https://staging.acobesmart.com/api/sensor/lastOnline

Query Metrics

6 Database Queries
6 Different statements
5.36 ms Query time
2 Invalid entities

Queries

Group similar statements

default connection

# Time Info
1 2.49 ms
SELECT t0.created_at AS created_at_1, t0.updated_at AS updated_at_2, t0.id AS id_3, t0.sensor_id AS sensor_id_4, t0.phone AS phone_5, t0.email AS email_6, t0.state AS state_7, t0.start_of_monitoring AS start_of_monitoring_8, t0.sim_number AS sim_number_9, t0.provider AS provider_10, t0.lte_valid_until AS lte_valid_until_11, t0.last_online AS last_online_12, t0.installed AS installed_13, t0.serial AS serial_14, t0.observer_last_online AS observer_last_online_15, t0.name AS name_16, t0.observer_version AS observer_version_17, t0.observer_state AS observer_state_18, t0.port AS port_19, t0.tga_hash AS tga_hash_20, t0.pending_command AS pending_command_21, t0.update_started_at AS update_started_at_22, t0.update_status AS update_status_23, t0.connection_type AS connection_type_24, t0.connection_type_override AS connection_type_override_25, t0.router_mac AS router_mac_26, t0.connection_checked_at AS connection_checked_at_27, t0.trade_id AS trade_id_28, t29.created_at AS created_at_30, t29.updated_at AS updated_at_31, t29.id AS id_32, t29.name AS name_33, t29.state AS state_34, t29.manufacturer_number AS manufacturer_number_35, t29.build_year AS build_year_36, t29.stops AS stops_37, t29.height AS height_38, t29.last_zues AS last_zues_39, t29.next_zues AS next_zues_40, t29.last_inspection AS last_inspection_41, t29.last_maintenance AS last_maintenance_42, t29.payload AS payload_43, t29.drive_type AS drive_type_44, t29.two_sided AS two_sided_45, t29.speed AS speed_46, t29.next_maintenance AS next_maintenance_47, t29.awm_state AS awm_state_48, t29.tuev_state AS tuev_state_49, t29.last_zues_type AS last_zues_type_50, t29.pnae_result AS pnae_result_51, t29.doors_have_measuring_point AS doors_have_measuring_point_52, t29.trip_value AS trip_value_53, t29.door_value AS door_value_54, t29.cabinlight_value AS cabinlight_value_55, t29.flushness_value AS flushness_value_56, t29.power_value AS power_value_57, t29.sk_front_value AS sk_front_value_58, t29.sk_back_value AS sk_back_value_59, t29.sk_hoist_value AS sk_hoist_value_60, t29.collective_disorder_value AS collective_disorder_value_61, t29.sap_nr AS sap_nr_62, t29.tuev_nr AS tuev_nr_63, t29.type_of_elevator AS type_of_elevator_64, t29.door_counter_divider AS door_counter_divider_65, t29.tga_hash AS tga_hash_66, t29.time_to_escalate_zues AS time_to_escalate_zues_67, t29.time_to_escalate_awm AS time_to_escalate_awm_68, t29.time_to_escalate_bs AS time_to_escalate_bs_69, t29.zues_disposal_until AS zues_disposal_until_70, t29.zues_disposal AS zues_disposal_71, t29.zues712 AS zues712_72, t29.zues_verfification AS zues_verfification_73, t29.zues_verfification_date AS zues_verfification_date_74, t29.technical_place AS technical_place_75, t29.has_warning AS has_warning_76, t29.repair_start AS repair_start_77, t29.maintenance_start AS maintenance_start_78, t29.zues_start AS zues_start_79, t29.repair_renewal_minutes AS repair_renewal_minutes_80, t29.maintenance_renewal_minutes AS maintenance_renewal_minutes_81, t29.zues_renewal_minutes AS zues_renewal_minutes_82, t29.power_failure AS power_failure_83, t29.sc_front_doors_failure AS sc_front_doors_failure_84, t29.collective_disorder_failure AS collective_disorder_failure_85, t29.state_lis AS state_lis_86, t29.send_to_api AS send_to_api_87, t29.intercorp_enabled AS intercorp_enabled_88, t29.smoke_extraction_collective_disorder AS smoke_extraction_collective_disorder_89, t29.comment AS comment_90, t29.control_link AS control_link_91, t29.bs_date AS bs_date_92, t29.anomaly_count AS anomaly_count_93, t29.water_level_warning AS water_level_warning_94, t29.has_waterlevel_warning AS has_waterlevel_warning_95, t29.awm_compatible AS awm_compatible_96, t29.els1_mqtt_host AS els1_mqtt_host_97, t29.els1_mqtt_port AS els1_mqtt_port_98, t29.els1_mqtt_psk_identity AS els1_mqtt_psk_identity_99, t29.els1_mqtt_psk AS els1_mqtt_psk_100, t29.awm_connect_id AS awm_connect_id_101, t29.has_awm_connect AS has_awm_connect_102, t29.check_disabled_security_circuit AS check_disabled_security_circuit_103, t29.check_disabled_power AS check_disabled_power_104, t29.check_disabled_flushness AS check_disabled_flushness_105, t29.check_disabled_collective_disorder AS check_disabled_collective_disorder_106, t29.check_disabled_malfunction AS check_disabled_malfunction_107, t29.check_disabled_smoke_extraction AS check_disabled_smoke_extraction_108, t29.check_disabled_water_level_warning AS check_disabled_water_level_warning_109, t29.check_disabled_aco_door_movements AS check_disabled_aco_door_movements_110, t29.check_disabled_flapping AS check_disabled_flapping_111, t29.has_standby_mode AS has_standby_mode_112, t29.in_standby AS in_standby_113, t29.standby_since AS standby_since_114, t29.standby_detected_at AS standby_detected_at_115, t29.check_disabled_aco_anomaly AS check_disabled_aco_anomaly_116, t29.aco_anomaly_suspect AS aco_anomaly_suspect_117, t29.aco_anomaly_since AS aco_anomaly_since_118, t29.aco_anomaly_snoozed_until AS aco_anomaly_snoozed_until_119, t29.aco_disconnect_suspect AS aco_disconnect_suspect_120, t29.aco_disconnect_since AS aco_disconnect_since_121, t29.aco_disconnect_restart_at AS aco_disconnect_restart_at_122, t29.deleted_at AS deleted_at_123, t29.address_id AS address_id_124, t29.trade_id AS trade_id_125, t29.manufacturer_id AS manufacturer_id_126, t29.maintenance_company_id AS maintenance_company_id_127, t29.control_company_id AS control_company_id_128, t29.custodian_company_id AS custodian_company_id_129, t29.lift_manager_company_id AS lift_manager_company_id_130, t29.sensor_id AS sensor_id_131, t29.client_id AS client_id_132, t29.operator_id AS operator_id_133, t29.service_company_id AS service_company_id_134, t29.contact_hauswart_id AS contact_hauswart_id_135, t29.contact_leitwarte_id AS contact_leitwarte_id_136, t29.contact_verwaltung_id AS contact_verwaltung_id_137, t29.contact_maintenance_company_id AS contact_maintenance_company_id_138, t29.contact_techniker_id AS contact_techniker_id_139, t29.install_company_id AS install_company_id_140, t29.mb_company_id AS mb_company_id_141, t29.client_aco_id AS client_aco_id_142, t29.leg_api_max_request_id AS leg_api_max_request_id_143, t144.id AS id_145, t144.created_at AS created_at_146, t144.updated_at AS updated_at_147, t144.state AS state_148, t144.voltage AS voltage_149, t144.has_warning AS has_warning_150, t144.tga_hash AS tga_hash_151, t144.technical_place AS technical_place_152, t144.manufacturer_number AS manufacturer_number_153, t144.last_inspection AS last_inspection_154, t144.last_maintenance AS last_maintenance_155, t144.last_zues AS last_zues_156, t144.next_zues AS next_zues_157, t144.next_maintenance AS next_maintenance_158, t144.manufacturer AS manufacturer_159, t144.type_of_pump AS type_of_pump_160, t144.build_year AS build_year_161, t144.liquid_level AS liquid_level_162, t144.threshold_value AS threshold_value_163, t144.apower AS apower_164, t144.current AS current_165, t144.pump_duration AS pump_duration_166, t144.last_pumpprocess_start AS last_pumpprocess_start_167, t144.last_pumpprocess_end AS last_pumpprocess_end_168, t144.address_id AS address_id_169, t144.trade_id AS trade_id_170, t144.maintenance_company_id AS maintenance_company_id_171, t144.sensor_id AS sensor_id_172, t144.client_id AS client_id_173, t144.operator_id AS operator_id_174, t144.install_company_id AS install_company_id_175, t176.created_at AS created_at_177, t176.updated_at AS updated_at_178, t176.id AS id_179, t176.name AS name_180, t176.state AS state_181, t176.fill_level AS fill_level_182, t176.manufacturer_number AS manufacturer_number_183, t176.build_year AS build_year_184, t176.last_zues AS last_zues_185, t176.next_zues AS next_zues_186, t176.last_inspection AS last_inspection_187, t176.last_maintenance AS last_maintenance_188, t176.next_maintenance AS next_maintenance_189, t176.tuev_state AS tuev_state_190, t176.electric_utility AS electric_utility_191, t176.type AS type_192, t176.tank_capacity AS tank_capacity_193, t176.power_generation_general AS power_generation_general_194, t176.tank_probe AS tank_probe_195, t176.tank_volume AS tank_volume_196, t176.number_of_probes AS number_of_probes_197, t176.probe1percent AS probe1percent_198, t176.probe2percent AS probe2percent_199, t176.probe3percent AS probe3percent_200, t176.battery_monitoring AS battery_monitoring_201, t176.tank_capacity_more_than AS tank_capacity_more_than_202, t176.battery_undervoltage AS battery_undervoltage_203, t176.ticket_for_tank_volume AS ticket_for_tank_volume_204, t176.tank_capacity_less_than AS tank_capacity_less_than_205, t176.leckage AS leckage_206, t176.value_for_collective_disorder AS value_for_collective_disorder_207, t176.value_for_probe AS value_for_probe_208, t176.aggregat_running AS aggregat_running_209, t176.value_for_ready_for_operation AS value_for_ready_for_operation_210, t176.value_for_generator_operation AS value_for_generator_operation_211, t176.value_for_mains_operation AS value_for_mains_operation_212, t176.value_for_mains_failure AS value_for_mains_failure_213, t176.value_for_charging_fault AS value_for_charging_fault_214, t176.value_for_transducer_failure AS value_for_transducer_failure_215, t176.value_for_deep_discharge_protection AS value_for_deep_discharge_protection_216, t176.value_for_leak_message AS value_for_leak_message_217, t176.value_for_battery_undervoltage AS value_for_battery_undervoltage_218, t176.value_for_aggregate_running AS value_for_aggregate_running_219, t176.value_for_function_test AS value_for_function_test_220, t176.config AS config_221, t176.value_for_net_failure AS value_for_net_failure_222, t176.value_for_operational AS value_for_operational_223, t176.tank_state AS tank_state_224, t176.deep_discharge_protection AS deep_discharge_protection_225, t176.charging_fault AS charging_fault_226, t176.transducer_failure AS transducer_failure_227, t176.collective_disorder AS collective_disorder_228, t176.ready_for_operation AS ready_for_operation_229, t176.tga_hash AS tga_hash_230, t176.time_to_escalate_tanken AS time_to_escalate_tanken_231, t176.time_to_escalate_bs AS time_to_escalate_bs_232, t176.technical_place AS technical_place_233, t176.repair_start AS repair_start_234, t176.maintenance_start AS maintenance_start_235, t176.zues_start AS zues_start_236, t176.repair_renewal_minutes AS repair_renewal_minutes_237, t176.address_id AS address_id_238, t176.manufacturer_id AS manufacturer_id_239, t176.maintenance_company_id AS maintenance_company_id_240, t176.control_company_id AS control_company_id_241, t176.tank_company_id AS tank_company_id_242, t176.service_company_id AS service_company_id_243, t176.custodian_company_id AS custodian_company_id_244, t176.client_id AS client_id_245, t176.sensor_id AS sensor_id_246, t176.trade_id AS trade_id_247, t176.contact_verwaltung_id AS contact_verwaltung_id_248, t176.contact_hauswart_id AS contact_hauswart_id_249, t176.contact_wartung_id AS contact_wartung_id_250, t176.contact_tank_company_id AS contact_tank_company_id_251, t176.contact_leitwarte_id AS contact_leitwarte_id_252, t176.operator_id AS operator_id_253, t176.contact_techniker_id AS contact_techniker_id_254, t176.install_company_id AS install_company_id_255 FROM sensor t0 LEFT JOIN elevator t29 ON t29.sensor_id = t0.id AND ((t29.deleted_at IS NULL)) LEFT JOIN pump t144 ON t144.sensor_id = t0.id LEFT JOIN nea t176 ON t176.sensor_id = t0.id WHERE t0.serial = ? LIMIT 1
Parameters:
[
  "10000000cd01789c"
]
2 0.22 ms
SELECT t0.id AS id_1, t0.cabinlight AS cabinlight_2, t0.flushness AS flushness_3, t0.securitychain AS securitychain_4, t0.power AS power_5, t0.created_at AS created_at_6, t0.updated_at AS updated_at_7, t0.elevator_id AS elevator_id_8 FROM awm t0 WHERE t0.elevator_id = ?
Parameters:
[
  827
]
3 0.21 ms
SELECT t0.id AS id_1, t0.trips_since_last_malfunction AS trips_since_last_malfunction_2, t0.trips_since_last_zues AS trips_since_last_zues_3, t0.trips_since_last_maintenance AS trips_since_last_maintenance_4, t0.last_trip AS last_trip_5, t0.trips AS trips_6, t0.doors_since_last_malfunction AS doors_since_last_malfunction_7, t0.doors_since_last_zues AS doors_since_last_zues_8, t0.doors_since_last_maintenance AS doors_since_last_maintenance_9, t0.doors AS doors_10, t0.trip_stats AS trip_stats_11, t0.aco_disorder_date AS aco_disorder_date_12, t0.elevator_id AS elevator_id_13 FROM stats t0 WHERE t0.elevator_id = ?
Parameters:
[
  827
]
4 0.10 ms
"START TRANSACTION"
Parameters:
[]
5 0.30 ms
UPDATE sensor SET state = ?, last_online = ?, updated_at = ? WHERE id = ?
Parameters:
[
  1
  "2026-08-20 17:10:38"
  "2026-08-20 17:10:38"
  409
]
6 2.04 ms
"COMMIT"
Parameters:
[]

newserver connection

No database queries were performed.

Database Connections

Name Service
default doctrine.dbal.default_connection
newserver doctrine.dbal.newserver_connection

Entity Managers

Name Service
default doctrine.orm.default_entity_manager
newserver doctrine.orm.newserver_entity_manager

Second Level Cache

Second Level Cache is not enabled.

Entities Mapping

default entity manager

Class Mapping errors
App\Entity\Sensor No errors.
App\Entity\CompanyMembershipProfile No errors.
App\Entity\Trade No errors.
App\Entity\Elevator No errors.
App\Entity\Address No errors.
App\Entity\Manufacturer No errors.
App\Entity\Company
  • The association App\Entity\Company#installSensors refers to the owning side field App\Entity\Sensor#installCompany which does not exist.
App\Entity\Contact No errors.
App\Entity\Client No errors.
App\Entity\LegApiMaxRequest No errors.
App\Entity\Ticket No errors.
App\Entity\Pump
  • The association App\Entity\Pump#address refers to the inverse side field App\Entity\Address#pumps which does not exist.
  • The association App\Entity\Pump#trade refers to the inverse side field App\Entity\Trade#pumps which does not exist.
  • The association App\Entity\Pump#gpios refers to the owning side field App\Entity\Gpio#pump which does not exist.
  • The association App\Entity\Pump#maintenanceCompany refers to the inverse side field App\Entity\Company#maintainedPumps which does not exist.
  • The association App\Entity\Pump#client refers to the inverse side field App\Entity\Company#clientPumps which does not exist.
  • The association App\Entity\Pump#operator refers to the inverse side field App\Entity\Company#operatedPumps which does not exist.
  • The association App\Entity\Pump#installCompany refers to the inverse side field App\Entity\Company#installPumps which does not exist.
App\Entity\Nea No errors.
App\Entity\Gpio No errors.
App\Entity\SensorOnOfflineStats No errors.
App\Entity\Document No errors.
App\Entity\InstallElevator No errors.
App\Entity\ManualInspection No errors.
App\Entity\Awm No errors.
App\Entity\GpioValue No errors.
App\Entity\AwmError No errors.
App\Entity\ErrorProtocoll No errors.
App\Entity\ZuesInspection No errors.
App\Entity\Stats No errors.
App\Entity\ElevatorAcquisition No errors.
App\Entity\ApiStats No errors.
App\Entity\ElevatorStateHistory No errors.

newserver entity manager

No loaded entities.